A blinking garage door sensor light usually means the safety sensors are misaligned, obstructed, or have a wiring issue – and your door will refuse to close until the problem is fixed. A steady green light on the receiving sensor and a steady amber or green light on the sending sensor means everything is working correctly. If either light is blinking, off, or showing an unexpected color, the sensors need attention. Advanced Door, Utah’s #1 rated garage door company with 4.9 stars, same-day sensor diagnostics, and the only lifetime warranty on parts and labor in the state, can fix your sensor issue fast. Call (844) 971-3667 for same-day service across Utah.

Last updated: July 2026
Your garage door suddenly won’t close. You press the button and the opener clicks, the lights flash, but the door just sits there – or worse, it starts to move and immediately reverses back up. You look at the sensors at the bottom of the door frame and notice something you’ve never paid attention to before: one of those little lights is blinking.
What does it mean? Is something broken? Can you fix it yourself, or do you need a professional?
Those small lights on your garage door sensors are actually a built-in diagnostic system. Every color, pattern, and combination tells you exactly what’s wrong – if you know how to read them. The problem is that most homeowners have never been taught what their sensor lights mean, and every brand uses a slightly different system.
This guide decodes every sensor light color, pattern, and combination for all major garage door opener brands. Whether your sensor is blinking red, showing one green and one amber, completely dark, or flashing in a pattern you’ve never seen before, you’ll find the answer here – along with exactly what to do about it.
Table of Contents
- How Garage Door Safety Sensors Work
- What Every Sensor Light Color Means
- Brand-by-Brand Sensor Light Guide
- Quick Diagnostic Table: Light Pattern to Problem
- 8 Common Causes of Blinking Sensor Lights
- DIY Troubleshooting Checklist
- Sun Interference: Utah’s #1 Sensor Problem
- How Utah’s Climate Affects Sensor Performance
- When to Call a Pro
- Sensor Repair and Replacement Costs
- How to Prevent Sensor Problems
- Frequently Asked Questions
How Garage Door Safety Sensors Work
Every garage door opener manufactured after January 1, 1993 is required by federal law (UL 325) to include photo-eye safety sensors. These sensors prevent the door from closing on people, pets, or objects in the doorway.
The system uses two sensors mounted on either side of the garage door opening, roughly 4-6 inches above the floor:
- Sending sensor (transmitter): Emits an invisible infrared beam across the doorway. Usually identified by an amber or green LED light.
- Receiving sensor (receiver): Detects the infrared beam from the sending sensor. Usually identified by a green LED light.
When the infrared beam is unbroken between the two sensors, the system gives the opener a “clear” signal and the door can close normally. When the beam is blocked or interrupted – by a person, a bicycle, a pet, debris, or even bright sunlight – the sensors tell the opener to stop or reverse the door.
The LED lights on each sensor are your window into the system’s status. They tell you whether power is reaching the sensors, whether the beam is aligned, and whether the system is functioning correctly.
Pro Tip
The sending sensor (transmitter) light indicates power status only – it glows steady regardless of alignment. The receiving sensor (receiver) light is the diagnostic one – it tells you whether the beam is being received. If the receiver light is blinking or off, that’s where your problem is.
What Every Sensor Light Color Means
Sensor light colors and their meanings vary slightly by brand, but there’s a universal logic to the system. Here’s what each light state means across all major garage door opener brands:
Green Light (Steady)
A steady green light on either sensor means “everything is working.” On the receiving sensor, steady green means the infrared beam is being received clearly and the sensors are properly aligned. On the sending sensor, steady green (used by some brands instead of amber) means the sensor has power.
Amber/Orange/Yellow Light (Steady)
A steady amber light on the sending sensor means the sensor has power and is transmitting the infrared beam. This is the normal, healthy state for the sending sensor on LiftMaster, Chamberlain, and many other brands. The sending light glows steady amber whether or not the receiving sensor is picking up the signal.
Green Light (Blinking)
A blinking green light on the receiving sensor is the most common symptom homeowners see. It means the receiver is getting intermittent or no signal from the sender. The sensors are misaligned, something is partially blocking the beam, or there’s a wiring issue causing signal interruption. This is the “fix me” indicator.
Red Light (Steady or Blinking)
Some brands (particularly Genie and certain Craftsman models) use red lights instead of or alongside green. A steady red light on the sending sensor typically means the sensor has power. A blinking red light on the receiving sensor means misalignment or obstruction – the same meaning as a blinking green on other brands.
No Light at All
If a sensor light is completely off, it means the sensor has no power. This could be a wiring issue (cut, frayed, or disconnected wire), a bad connection at the opener, a blown fuse or tripped circuit breaker, or a failed sensor that needs replacement.
Safety Warning
Never bypass or disconnect your garage door sensors to make the door close. The sensors exist to prevent serious injuries and deaths. A closing garage door exerts 300-400 pounds of force – enough to injure a child or pet. If your sensors are malfunctioning, fix the root cause. Never use the wall button’s “hold to close” bypass as a permanent solution.
Brand-by-Brand Sensor Light Guide
LiftMaster and Chamberlain
LiftMaster (professional-grade) and Chamberlain (retail) are made by the same manufacturer and use identical sensor systems. Advanced Door installs LiftMaster openers and services both brands.
- Sending sensor: Steady amber light = normal (has power, transmitting)
- Receiving sensor: Steady green light = aligned and working
- Receiving sensor: Blinking green light = misaligned or obstructed
- Receiving sensor: No light = no power (wiring issue) or dead sensor
- Sending sensor: No light = no power reaching the sensor
- Both sensors flickering: Possible wiring short, check for damaged wires along the track
On newer LiftMaster models with Security+ 2.0, the opener unit’s diagnostic LED will also blink a specific pattern when sensor issues are detected – typically 10 blinks for “safe-T-beam” errors. See our LiftMaster troubleshooting guide for full LED code details.
Genie
Genie uses a different color system than LiftMaster/Chamberlain, which can confuse homeowners switching between brands.
- Sending sensor: Steady red light = normal (has power, transmitting)
- Receiving sensor: Steady green light = aligned and working
- Receiving sensor: Blinking green or off = misaligned or obstructed
- Receiving sensor: No light = no power or dead sensor
- Both lights steady but door won’t close: Check for “Safe-T-Beam” error on opener LED
On Genie Intellicode models, the opener’s diagnostic LEDs provide additional troubleshooting codes. See our Genie troubleshooting guide for full details.
Craftsman
Craftsman openers were manufactured by Chamberlain Group (same sensors as LiftMaster/Chamberlain) or by Genie, depending on the model year and generation.
- Chamberlain-made Craftsman: Amber (sending) + green (receiving) – same as LiftMaster
- Genie-made Craftsman: Red (sending) + green (receiving) – same as Genie
- How to tell: Check the Learn button color on the opener motor unit. Purple/yellow/orange = Chamberlain-made. Older square buttons = may be Genie-made.
- Receiving sensor blinking: Misalignment on either type
Since Sears discontinued Craftsman openers, replacement sensors can be hard to find. Many Craftsman sensors are cross-compatible with LiftMaster or Chamberlain sensors. See our Craftsman troubleshooting guide for model-specific help.
Linear
Linear openers (which Advanced Door also installs) use a straightforward sensor light system:
- Sending sensor: Steady green light = normal
- Receiving sensor: Steady green light = aligned and working
- Receiving sensor: Blinking or off = misaligned, obstructed, or no power
- Both sensors green but door won’t close: Check wiring connections at the opener terminal
Overhead Door (Genie OEM)
Many Overhead Door branded openers use Genie-manufactured sensors with red/green indicator lights. Follow the Genie guide above for troubleshooting.
Pro Tip
Not sure which brand your sensors are? Look for a label on the sensor body itself, or check the opener motor unit on the ceiling – the brand name is usually on the front or side. If you still can’t tell, call Advanced Door at (844) 971-3667 and describe what you see. We service every major brand.
Quick Diagnostic Table: Light Pattern to Problem
| What You See | What It Means | Likely Cause | DIY Fix? |
|---|---|---|---|
| Sending: steady amber/green. Receiving: steady green. | Normal – sensors working correctly | No issue with sensors | N/A |
| Sending: steady. Receiving: blinking green. | Beam interrupted or weak signal | Misalignment, obstruction, or dirty lens | Yes – clean and realign |
| Sending: steady. Receiving: completely off. | Receiver has no power | Broken wire, loose connection, or dead sensor | Maybe – check wiring |
| Sending: off. Receiving: off. | No power to either sensor | Wiring issue at opener, power outage, blown fuse | Maybe – check breaker and connections |
| Sending: off. Receiving: steady green. | Sender has no power but receiver does | Broken sender wire or failed sending sensor | Unlikely – needs sensor replacement |
| Both sensors flickering rapidly. | Electrical interference or short | Damaged wiring, water intrusion, or RF interference | No – call a pro |
| Both steady but door still won’t close. | Sensors OK – problem is elsewhere | Travel limits, force settings, or mechanical issue | Maybe – see troubleshooting guide |
| Receiving: green in morning, blinking in afternoon. | Sun interference | Direct sunlight overwhelming infrared beam | Yes – shade the sensor |
| Lights normal, door closes partway then reverses. | Beam broken during closing | Vibration shaking sensor out of alignment during operation | Maybe – tighten bracket and realign |
8 Common Causes of Blinking Sensor Lights
1. Misaligned Sensors
The most common cause of blinking sensor lights. The two sensors must be aimed directly at each other to maintain the infrared beam. Even a slight bump from a bicycle, lawnmower, trash can, or child playing in the garage can knock a sensor out of alignment. The sending sensor continues to glow steady (it doesn’t know the receiver can’t see it), while the receiving sensor blinks because the beam isn’t landing on its photo-eye.
For a complete step-by-step alignment procedure, see our sensor alignment guide.
2. Dirty or Obstructed Lenses
Dust, cobwebs, dirt, pollen, and garage grime accumulate on the small plastic lenses on each sensor. Even a thin film of dust can weaken the infrared signal enough to cause intermittent blinking. In Utah, this is especially common during spring (pollen), summer (dust), and construction season near new developments.
3. Sun Interference
Sunlight contains infrared wavelengths that can overwhelm the receiving sensor’s ability to detect the transmitter’s beam. This is the most common warm-weather sensor problem in Utah – especially for west-facing and south-facing garages during afternoon hours. The classic symptom is a door that works fine in the morning but won’t close between 2-6 PM. See the dedicated sun interference section below.
4. Damaged or Cut Wiring
The thin wires running from each sensor back to the opener motor unit are vulnerable to damage. Common causes include:
- Wires pinched or cut by closing the garage door on them
- Wires chewed by mice or other rodents (common in Utah garages)
- Wires pulled loose at the terminal connections on the opener
- Wires rubbing against the garage door track and wearing through insulation
- Corrosion at wire connections from moisture exposure
5. Moisture and Condensation
Water inside or on the sensor lens causes light refraction that disrupts the infrared beam. In Utah, this happens during spring snowmelt when water seeps under the garage door, during summer monsoon storms with wind-driven rain, and during fall/winter when temperature swings create condensation on cold sensor bodies.
6. Sensor Bracket Vibration
The metal brackets that hold sensors in position can loosen over time from the vibration of the garage door opening and closing thousands of times. When the bracket is loose, the sensor may be aligned when the door is at rest but vibrate out of alignment during operation – causing the door to reverse partway through closing.
7. Failed Sensor
Sensors don’t last forever. The LED inside the sensor, the photo-eye detector, or the internal circuit board can fail after years of use, especially with exposure to temperature extremes, moisture, and UV light. Average sensor lifespan is 7-12 years, though Utah’s harsh conditions can shorten that to 5-8 years. If you’ve cleaned, realigned, and checked all wiring and the sensor still won’t show a steady light, the sensor likely needs replacement.
8. Electrical Interference
LED shop lights, fluorescent fixtures, and certain electronic devices in the garage can emit infrared or radio frequencies that interfere with sensor communication. This is more common than most homeowners realize. If your sensor problems started after installing new garage lighting, that’s likely the culprit.
Utah Note
Utah homeowners deal with sensor issues more frequently than the national average due to our extreme temperature swings (up to 50+ degrees in a single day during spring/fall), intense UV exposure at elevation (4,200-6,000+ feet along the Wasatch Front), fine dust from dry conditions, and road salt residue that corrodes wiring and connections. If your sensors seem to need constant attention, the Utah climate may be accelerating wear.
DIY Troubleshooting Checklist
Before calling a professional, try these safe fixes in order. Most blinking sensor lights can be resolved with one of the first three steps:
Action Step
Step 1: Clear the path. Look along the entire bottom of the door opening between the two sensors. Remove anything that could be blocking the beam: boxes, bags, tools, toys, garden hoses, shoes, cobwebs. The beam is only 4-6 inches above the floor, so even small items can block it.
Step 2: Clean the lenses. Use a soft, dry cloth (microfiber works best) to gently wipe both sensor lenses. Don’t use glass cleaner or chemicals – they can leave a residue that refracts the infrared beam. If the lenses are very dirty, use a slightly damp cloth and dry thoroughly.
Step 3: Check alignment. Look at both sensors from behind. The small LED indicators should be visible. Gently adjust the receiving sensor (the one with the blinking light) by loosening its wing nut, repositioning until the light turns steady green, then retightening. Our sensor alignment guide has detailed step-by-step instructions.
Step 4: Inspect wiring. Follow the thin wires from each sensor up to where they connect to the opener motor unit. Look for cuts, fraying, bare copper showing, pinch points, or loose connections at the terminals. If you find damage, this is typically a job for a professional.
Step 5: Check the bracket. Try gently pushing on each sensor. If it moves easily or wobbles, the mounting bracket is loose. Tighten the wing nut or bolt that holds the sensor to the bracket, then realign.
Step 6: Power cycle the opener. Unplug the opener from the ceiling outlet (or turn off the breaker) for 30 seconds, then restore power. This resets the sensor circuit and can clear intermittent electronic glitches.
Step 7: Test for sun interference. If the problem only happens at certain times of day, hold your hand or a piece of cardboard above the receiving sensor to shade it from direct sunlight. If the light goes steady, sun interference is your problem.
Step 8: Test for light interference. Turn off all lights in the garage (especially LED shop lights and fluorescent tubes) and see if the sensor light goes steady. If it does, your garage lighting is interfering with the sensors.
If none of these steps resolve the blinking light, the sensor likely has an internal failure and needs professional diagnosis or replacement. Call Advanced Door at (844) 971-3667.
Sun Interference: Utah’s #1 Sensor Problem
In Utah, sun interference is the single most common cause of seasonal sensor problems – and July is the worst month for it. Here’s why:
The infrared beam your sending sensor emits operates on a specific wavelength. When intense direct sunlight – which is loaded with infrared energy – hits the receiving sensor, it floods the photo-eye with so much infrared light that it can’t distinguish the transmitter’s beam from the ambient sunlight. The receiving sensor “sees” a wall of infrared and can’t find the signal, so the light blinks.
Why Utah Is Especially Bad for Sun Interference
- High elevation = more intense sunlight. Utah’s Wasatch Front sits at 4,200-6,000+ feet, meaning less atmosphere filtering UV and infrared radiation. Sun intensity is 15-25% higher than at sea level.
- Clear skies dominate. Utah averages 222 sunny days per year. Fewer clouds mean more direct solar exposure on sensors.
- Long summer days. In July, Utah gets 14-15 hours of daylight, with the sun at extreme angles during morning and evening that can shine directly into garage openings.
- East-west street orientation. Many Utah subdivisions have streets running east-west, which means garage doors face north or south – and south-facing doors get direct afternoon sun blasting into the opening.
How to Fix Sun Interference
If your garage door works fine in the morning but won’t close in the afternoon (or vice versa), sun interference is almost certainly the cause. Here are proven solutions:
- Swap sensor positions. Move the receiving sensor to the side of the door that gets less direct sunlight. The sending sensor doesn’t care about sunlight – only the receiver is affected.
- Add a sun shade. A small piece of cardboard tube (like a toilet paper roll cut in half), PVC pipe section, or commercial sensor shield placed over the receiving sensor blocks ambient sunlight while allowing the horizontal infrared beam through. This is the easiest fix.
- Reposition sensor angle. Point the receiving sensor slightly downward so it’s aimed more at the sending sensor and away from the sun’s angle. Even a small tilt can make a difference.
- Upgrade to newer sensors. Modern LiftMaster sensors (like the 041D7511 and newer) have improved sun rejection technology specifically designed for high-sun environments. If your sensors are 10+ years old, upgrading can permanently solve the problem.
Pro Tip
The toilet paper roll trick is the quickest sun shade fix – tape half a cardboard tube around the receiving sensor like a visor. It’s not pretty, but it works within seconds and lets you confirm sun interference is the issue before investing in a permanent solution. If it works, ask your technician about commercial sensor hoods during your next service call.
How Utah’s Climate Affects Sensor Performance
Utah’s climate creates unique challenges for garage door sensors that homeowners in milder regions don’t experience. Understanding these regional factors helps you anticipate and prevent sensor problems throughout the year.
Wasatch Front (Salt Lake City, Provo, Ogden)
- Winter inversions: Trapped cold air creates moisture and condensation on sensor lenses and wiring
- Road salt: UDOT’s aggressive road salt program generates corrosive salt spray that damages sensor wiring, terminals, and metal brackets. Garages near main roads are especially vulnerable.
- Temperature swings: 50+ degree daily temperature swings in spring and fall cause metal brackets to expand and contract, gradually loosening sensor mounts
Northern Utah (Logan, Brigham City, Cache Valley)
- Extreme cold: Winter temperatures regularly drop below zero, which causes wire insulation to become brittle and crack, exposing copper to moisture
- Heavy snowfall: Snow and ice buildup at the base of the door can physically push sensors out of alignment or block the beam entirely
- Mice: Cold winters drive rodents into garages seeking warmth – and they chew sensor wires
Southern Utah (St. George, Cedar City)
- Extreme heat: Summer temperatures above 110 degrees can cause sensor electronics to overheat and temporarily malfunction
- UV degradation: Intense UV exposure degrades plastic sensor housings and lenses over time, turning them cloudy and reducing infrared transmission
- Sand and dust: Fine desert particles coat sensor lenses and work into connections
Mountain Communities (Park City, Heber, Brian Head)
- Altitude: Higher elevations mean even more intense UV and temperature extremes
- Vacation homes: Sensors in infrequently used garages can accumulate significant debris, cobwebs, and moisture damage between visits
- Wildlife: Spiders and insects in mountain areas build webs directly across sensor beams
When to Call a Pro
While many sensor issues are DIY-fixable, some situations require professional diagnosis and repair. Call a technician when:
- You’ve tried all 8 DIY steps and the light is still blinking or off
- Wires are damaged – cut, frayed, or showing bare copper
- Sensors are physically broken – cracked housing, dangling from bracket, or water inside
- The problem is intermittent – works sometimes but not others (often indicates a wiring short)
- Both sensors are dark – could indicate an issue at the opener’s circuit board, not just the sensors
- Your sensors are more than 10 years old – replacement with modern sensors often costs less than multiple repair visits
- You’re not comfortable working near the garage door tracks – sensors are mounted near moving parts
- The opener’s diagnostic LED shows error codes beyond a simple sensor alignment issue
Sensor Repair and Replacement Costs
Understanding the typical cost range for sensor services helps you budget and evaluate quotes. These are industry-standard price ranges for the Utah market:
| Service | Typical Cost Range | Includes |
|---|---|---|
| Sensor alignment only | $75 – $125 | Inspection, cleaning, realignment, testing |
| Wire repair (single sensor) | $100 – $175 | Locate break, splice or re-run wire, test |
| Complete re-wiring (both sensors) | $150 – $250 | New wire run from opener to both sensors |
| Single sensor replacement | $100 – $200 | New sensor, mounting, wiring, alignment |
| Both sensors replacement (pair) | $150 – $275 | Sensor pair, mounting, wiring, alignment |
| Sensor bracket replacement | $50 – $100 | New bracket, remount, alignment |
| Sun shield installation | $25 – $75 | Commercial sun hood, mounting, testing |
| Sensor upgrade (newer model) | $150 – $300 | Modern sensors with better sun rejection, new wiring |
Advanced Door provides free estimates for all sensor services. Our technicians diagnose the issue on-site and give you the exact cost before any work begins – no surprises. Call (844) 971-3667 for same-day sensor diagnostics.
How to Prevent Sensor Problems
Most sensor issues are preventable with minimal maintenance. Add these checks to your regular garage door routine:
Monthly (30 Seconds)
- Glance at both sensor lights when closing the door – both should be steady
- Look for cobwebs or debris near the sensor lenses
Quarterly (5 Minutes)
- Wipe both sensor lenses with a soft dry cloth
- Check that both sensors are firmly mounted (no wobble)
- Verify the auto-reverse safety test (place a 2×4 flat on the floor under the door and close – the door should reverse when it contacts the board)
Annually (During Tune-Up)
- Inspect all sensor wiring for damage, fraying, or rodent chewing
- Check terminal connections at the opener for corrosion or looseness
- Test sensor alignment precision (even if lights look steady, alignment can drift over time)
- Replace sensors that are 10+ years old before they fail
Seasonal (Utah-Specific)
- Spring: Clean road salt residue from wiring, brackets, and sensor bodies. Check for winter freeze/thaw damage to wire insulation.
- Summer: Test for sun interference during peak afternoon hours. Add sun shields if needed. Check for dust buildup.
- Fall: Clear leaves and debris from the sensor area. Verify alignment before winter.
- Winter: Keep the area around sensors clear of snow and ice. Check for rodent damage to wiring.
Action Step
Schedule your garage door sensors into your seasonal home maintenance routine. A 30-second monthly glance at the sensor lights catches problems before they leave you stuck with a door that won’t close. For a complete garage door maintenance schedule including sensors, springs, rollers, and more, see our maintenance schedule guide.
Frequently Asked Questions
Why is my garage door sensor blinking green?
A blinking green light on the receiving sensor means it is not receiving the infrared beam from the sending sensor. The most common causes are misalignment, a dirty lens, an obstruction in the beam path, or sun interference. Try cleaning both lenses, clearing the path between sensors, and gently realigning the receiving sensor until the light turns steady green.
What does it mean when one garage door sensor is green and the other is amber?
This is actually the normal, healthy state for most garage door sensor systems. On LiftMaster and Chamberlain openers, the sending sensor shows a steady amber light (indicating power) and the receiving sensor shows a steady green light (indicating proper alignment). If both lights are steady, your sensors are working correctly.
Why does my garage door sensor only blink in the afternoon?
Afternoon blinking is almost always caused by sun interference. As the sun moves to a lower angle in the afternoon, direct sunlight can hit the receiving sensor and overwhelm the infrared beam. This is especially common in Utah due to our high elevation and clear skies. Try shading the receiving sensor, swapping sensor positions, or upgrading to modern sensors with better sun rejection.
Can I bypass my garage door sensors to make the door close?
You should never permanently bypass your garage door sensors. They are a federal safety requirement (UL 325) that prevents the door from closing on people, children, and pets. A closing garage door exerts 300-400 pounds of force. In an emergency, most openers allow you to hold the wall button continuously to close the door while overriding the sensors – but this should only be used as a temporary measure while you fix the root cause.
How long do garage door sensors last?
Garage door sensors typically last 7-12 years, though Utah’s extreme temperatures, UV exposure, road salt, and dust can reduce lifespan to 5-8 years. If your sensors are 10+ years old and having repeated issues, replacement is usually more cost-effective than continued repairs. Modern sensors have improved sun rejection, weather resistance, and signal strength.
Why are both my garage door sensor lights off?
If both sensor lights are completely dark, the sensors are not receiving power. Check your circuit breaker first – it may have tripped. Next, verify the opener is powered on (the light on the motor unit should be working). If the opener has power but the sensors don’t, there’s likely a wiring issue between the opener and the sensors – a broken wire, loose terminal connection, or damaged wire junction. This typically requires professional repair.
My sensor lights are steady but my door still won’t close. What’s wrong?
If both sensor lights are steady and the door still won’t close, the problem is not with the sensors. Common causes include misadjusted travel limits, incorrect force settings, a mechanical obstruction, a problem with the wall button or remote, or an issue with the opener’s logic board. See our complete troubleshooting guide or our door won’t close guide for help diagnosing non-sensor closing issues.
Do I need to replace both sensors at the same time?
You don’t always need to replace both sensors at the same time, but it’s often recommended. If one sensor has failed after 8+ years, the other sensor is likely nearing the end of its life too. Replacing both ensures matched components and eliminates the risk of the second sensor failing shortly after the first repair. The cost difference between replacing one sensor versus a pair is typically only $50-75, making a pair replacement the better value in most cases.
Get a Free Estimate from Advanced Door
Sensor blinking, dark, or acting up? We diagnose and fix every brand – same day.
Serving Ogden, Salt Lake City, Provo, Park City, Logan, and all of Utah
Call for a free estimate. No pressure, no hidden fees.
Current offers: $100 off any new door or 10% off any service call
(Offers cannot be combined)